FRP plate lighting installation guide
Provides lap
1, lighting board edge overlap should be ≤ 1.5 wave (sine wave) or ≤ 1 peaks (trapezoidal wave)
2, the end of lap Size
| 屋面坡度 |
端面最小搭接量(cm) |
| >1:10 |
15 |
| 1:15~1:10 |
25~30 |
Vertical plate |
10 |
3, extend the length of the eaves of the house should not exceed 23 cm
4, eaves, roof and around the edge should be pressure and Seal.
Minimum roof slope shall not be less than 1:15.
Tthe installation of lighting board Hole
1, does not allow punching, only bored. Aperture ratio fixed large 0.2 cm diameter bolts
2, washers diameter bolts should be not less than the diameter of 8 to 10 times
3, waveform fixed horizontal bolt spacing should be not more than 30 cm, and can also be specific waveform discretion. General fixed bolts in the peak (when more than 2.5 centimeters high peaks, the peaks must be fixed). As a last resort must be fixed in the trough, the right to choose reliable sealing gaskets to ensure that.
Affixed with anti-aging Wai film should be a place, in the pre-installation of membrane removed.
Plate and the edge of the plate and the end of the lap belt or polyethylene viscosity of the seal; shelved the end of the outer walls, the waveform can be sealed liner.
Tthe use of lighting plate bending, bending radius and the waveform and thickness. Generally do not bend radius is not in the four meters.
Flat at the time of installation, peripheral support and pressure should be, and be sealed.
|